Archive for November, 2016

This 1936 built mass concrete house in Dundrum Dublin 14 challenged us. Firstly the stove , like so many others, was an unsafe install, as the flue exited the rear, into a 90* bend, with the 5″  flue pipe  partially inserted into the 8″ clay liner without proper or safe adaptor. Secondly the depth of firechamber was only 11″, and it was constructed in mass concrete. Our client wanted the freestanding  stove recessed. Luckily our client located a wooden mantle, with an unusual rebate of 140mm (5.5″), allowing us  the option of  creating  a false front to the  chimney breast, achieving 16.5″. We lined the firechamber with Skamolex fireboard, and tiled the hearth and back panel with our clients yellow tiles. All in keeping with the house era. We installed a 904 grade flexi flue and insulated. If you are uncertain about the safety of your stove installation, contact Nick 0879501001  , Stove & Chimney SOotLUTIONS ,  www.stoveandchimney.net ,stoveandchimney@gmail.com 

​https://www.youtube.com/watch?v=k2XqlZlO5ts

WATCH   THE  VIDEO